Page 53: of Maritime Reporter Magazine (June 15, 1970)
Read this page in Pdf, Flash or Html5 edition of June 15, 1970 Maritime Reporter Magazine
CLYDE 17-DE-90 WHIRLEY CRANE
Lifting Rate: 25 tons @ 50 Ft. Radius @ 50 to 60 FPM.—
Boom: 80' to headblock (with 10' whip)
Whip: 10 tons @ 125 FPM—2 part line
Track Centers: 20'—Engine: Cummins HBIS 601, 180 HP supercharged, elec. start-
Motors: Each leg (4 tot.) 7Vz HP, 230 DC.—
Power: Diesel electric (DC)
ELECTRIC
MOTORS 230 VOLT D.C. MOTORS 1—250 HP, G.E., Type CY, Form HJ, Model 24G, 1200 RPM Horizontal, 2 B.B., Shunt Wd. 2—220 HP, G.E., Type CDM—1348S, Form HA,
Model 25G 339, 1800 RPM, Stab. Sh. Wd. Hori- zontal, 2 B.B. 6—100 HP, Westinghouse, Type SK, FR. 163, Style 1B4631, 1150 RPM, Shunt Wd. Horizontal, 2 B.B. 2—55 HP, Electro-Dynamic, FR 25.-SL, 550 RPM,
Compound Wound, Single Ball Bearing. Originally for high pressure Air Compressor. 6—50 HP, Westinghouse, 600 RPM, Compd. Wd.,
Type CK, FR 9, Horizontal, 2 B.B. 1—40 HP, Allis-Chalmers, 1750 RMP, Compound
Wound, Horizontal, 2 B.B. 1—65 HP, Westinghouse, 560 RPM, Type CK,
Frame 10, 260 Amperes, B.B., D.P., Compound
Wound. 2—220 HP, G.E., 1800 RPM, Type CDM-13485,
Model 25G339, 775 Amperes, B.B., D.P., Stab.
Shunt. 4—9.3 HP, Westinghouse, 640/852 RPM, Type SK,
FR. 93. 120 VOLT D.C. MOTORS 1—304 HP, Westinghouse, 900 RPM, Shunt Wound,
Horizontal, Pedestal Bearing. 3—25 HP, G.E., Type CDM, 1200 RPM, Horizontal, 2 B.B., unused. Removed from M.G. Sets. 6—7% HP, Westinghouse Type SR, FR 43, Stab.
Sh. Wd., 1750 RPM.
STEERING GEAR MOTORS 2—General Electric, 30 HP, 230 V, DC, 600 RPM,
Stab. Sh. Wd., Type CDM, Fields Continuous Duty,
Armature 1 Hr. 1—Westinghouse, 35 HP, 230 V, DC, 850 RPM,
Stab. Sh. Wd., Type SK, Fr. 123, Fields Continuous
Duty, Armature 1 Hr.
SHIP'S LIGHTING M-E SETS 230 V, DC/115 V, DC. Ship's Lighting M.G. Sets for
C3-S1-A-3 150 K.W. and Moore built C2 100 K.W.
SPECIAL D.C. GENERATORS 3—Unused, G.E., 15 KW, 100 A, 15 V, Type CDM, 1200 RPM, 2 B.B., D.P. Generators.
MOTOR-GENERATOR SETS
Unused Surplus in Original Boxes
Janette M-G Sets. Input: 1.75 HP, 230 V, DC, 7.2
Amperes, 1800 RPM. Output: 1-KVA (.85 KW), 115/1/60, 4 ball bearing, with speed regulator, and with noise filters. Navy Type CJM-21151, con- tinuous duty. Net weight 435#, Dimensions 44"
L, 19y2" W, 18%" H. Instruction book and parts list included.
D.C. MARINE CONTROLLERS 1—Cutler-Hammer, 250 HP, 230 V, DC,
No. 232 793A14. 2—General Electric, 225 HP, 230 V, DC,
CR 5430-B32D. 6—Westinghouse, 100 HP, 230 V, DC, Type 8585A SO-1B4636. 1—Cutler-Hammer, Unused, 50 HP, 230 V,
DC, No. C280981A290, Contactor Panel for
Stern Anchor Haulage Winch. Many others from % HP and up—115 and 230 V.
CIRCUIT BREAKERS 2 and 3 Pole Air Breakers, 2 and 3 Pole
Molded Case Navy Type Breakers, 2 and 3 Pole Trip Elements for Molded Case
Breakers. 115 VOLT DC FANS
Boost your ventilation with these econom- ical units as removed from service. These various brand products have been tested and are in operating order. 12" Bulkhead
Mounting
Oscillating $15.00 ea. 12" Bulkhead
Mounting, Non-
Oscillating $9.50 ea.
D.C. GENERATORS 2—500 KW, 120/240 V, Westinghouse FR.
CB813.7, 750 RPM, 2 Pedestal Bearing, with Bal- ance Coils. Removed from GM 8-278 Engines. 2—250 KW, 120/240 V, Westinghouse, 1200 RPM,
Single Pedestal Bearings. Balance Coils not avail- able, Type 12S18P107PH, removed from Turbines. 2—150 KW, 120 V, G.E., Type CDM-1348-S, Form
HA, Model 25G 340, 1800 RPM, Compound Wound,
Horizontal 2 B.B. 1—150, 120 V, G.E., Type CDM, Form AA, Model 24G, 1200 RPM, Compound Wound, Horizontal, 2
B.B. 6—100 KW, 120/240 V, Westinghouse, Type SK,
FR. 143.8, 1800 RPM, Single Ball Bearings. Bal- ance Coils available. 3—100 KW, 120/240 V, Delco, 1200 RPM, Single
Bushed Bearings, with Balance Coils. Removed from Superior GDB-8 Engines. 1—100 KW, 120/240 V, Allis-Chalmers, 1200
RPM, Single Sleeve Bearing, Shunt Wound, Type 4—14-45-13, removed from GM 3-268A Engine. 10—90/165 KW, Westinghouse, 125/400 Volt,
Type SK, FR. 185, Shunt Wound, separately ex- cited (120 V), 1200 RPM, Horizontal, 2 B.B. 4—75 KW, 120 V, G.E., Type CDM-1234, Mod. 24GA71,1200 RPM, 2 Ball Bearing, Tapered Shaft.
Removed from Motor-Generator Sets. 6—60 KW, 120 V, Westinghouse, Type SK, FR 143,
Style 3B2855-PH, 1800 RPM, 1 B.B. Removed from
Turbines. 6—60 KW, 120 V, Westinghouse, Type SK, FR. 153-L, Style 1B4632,1200 RPM, Compound Wound,
Horizontal, 2 B.B.
A.C. OR D.C. M-G SETS
From 250 Watts to 500 KW in 115 Volt, 230 Volt and 120/240 Volt, 3 Wire DC. Any drive including
Synchronous Motor. Let us have your inquiries. tremendous stock of electrical equipment at the right prices.
ZIDELL EXPLORATIONS, INC
Contact
Hugh Sturdivant (503) 228-8691 3121 S.W. Moody
Portland, Ore. 97201
Telex: 36-701
RECONDITIONED
MOTOR GENERATOR SETS o o yg -
TaT
Bogue. Input: 230 V, DC, 57A, 15 HP. Output: 10 KVA, PF .8, 120 V, 60 cy., 10.
Fidelity. Input: 15 HP, 230 V, DC. Output: 12.5
KVA, 10 KW, 120/1/60.
Bogue Electric. Input: 15 HP, 230 V, DC. Out- put: 12.5 KVA, 10 KW, 120/1/60.
Burke Electric. Input: 20 HP, 230 V, DC. Out- put: 25 KVA, 12.5 KW, 120/1/60.
Star Kimble. Input: 30 HP, 230 V, DC. Output: 25 KVA, 20 KW, 120/1/60.
Ideal. Input: 40 HP, 230 V, DC. Output: 31.3
KVA, 25 KW, 450/3/60.
Star. Elec. Input: 40 HP, 230 V, DC. Output: 33.4 KVA, 25 KW, 450/3/60.
General Elec. Input: 230 V, DC, 40 HP. Output: 25 KW, 480 V, 60 cy., 30, 34A, 1800 RPM.
Star Elec. Input: 125 HP, 240 V, DC, Output: 93.75 KVA, 75 KW, 450/3/60.
MANY SMALLER UNITS IN STOCK
Marathon. Input: 1 HP, 115 V, DC, Output: .500
KVA, .425 KW, 115/1/60.
Bludworth. Input: .75 HP, 115 V, DC, Output: .500 KVA, .450 KW, 115/1/60.
Century. Input: 1.5 HP, 115 V, DC. Output: .750
KVA, .600 KW, 125/1/60.
Elect. Prod. Input: 1.5 HP, 115 V, DC. Output: 1 KVA, 115/1/60.
Allis-Chalmers. Input: 14 Amp, 115 V, DC. Out- put: 1.250 KVA, 1 KW, 115/1/60.
Cont. Elect. Input: 6 HP, 115 V, DC. Output: 2.9
KW, 440/3/60.
Louis Allis. Input. 10 HP, 105/130 V, DC, Out- put: 7.5 KVA, 440/3/60.
Cont. Elect. Input: 12 HP, 120 V, DC. Output: 7.5 KVA, 440/3/60.
Continental. Input: 50 HP, 115 V, DC. Output: 50 KVA, 25 KW, 120/3/60.
Need 3 Wire 120/240 Volts DC for Shore Power? Motor-Generator Sets and Engine
Driven Units from 15 KW to 500 KW ... Let us quote.
INQUIRIES
INVITED ON:
Dry Transformers • AC & DC Gear
Motors • Centrifugal Fans • Propeller
Fans • Port Hole Fans • Bracket Fans • Salinity Panels • Salinity Indicator
Cells • Electric Telegraphs • Rudder
Angle Indicators • Diesel Engine
Starting Contactors • AC & DC
Switchboards
ALSO RADIO, RADAR & ELECTRONIC EQUIPMENT