CLYDE 17-DE-90 WHIRLEY CRANE

Lifting Rate: 25 tons @ 50 Ft. Radius @ 50 to 60 FPM.—

Boom: 80' to headblock (with 10' whip)

Whip: 10 tons @ 125 FPM—2 part line

Track Centers: 20'—Engine: Cummins HBIS 601, 180 HP supercharged, elec. start-

Motors: Each leg (4 tot.) 7% HP, 230 DC.—

Power: Diesel electric (DC)

ELECTRIC

MOTORS 230 VOLT D.C. MOTORS 1—250 HP, G.E., Type CY, Form HJ, Model 24G, 1200 RPM Horizontal, 2 B.B., Shunt Wd. 2—220 HP, G.E., Type CDM—-1348S, Form HA,

Model 25G 339, 1800 RPM, Stab. Sh. Wd. Hori- zontal, 2 B.B. 6—100 HP, Westinghouse, Type SK, FR. 163, Style 1B4631, 1150 RPM, Shunt Wd. Horizontal, 2 B.B. 2—55 HP, Electro-Dynamic, FR 25.-SL, 550 RPM,

Compound Wound, Single Ball Bearing. Originally for high pressure Air Compressor. 6—50 HP, Westinghouse, 600 RPM, Compd. Wd.,

Type CK, FR 9, Horizontal, 2 B.B. 1—40 HP, Allis-Chalmers, 1750 RMP, Compound

Wound, Horizontal, 2 B.B. 1—65 HP, Westinghouse, 560 RPM, Type CK,

Frame 10, 260 Amperes, B.B., D.P., Compound

Wound. 2—220 HP, G.E., 1800 RPM, Type CDM-13485,

Model 25G339, 775 Amperes, B.B., D.P., Stab.

Shunt. 4—9.3 HP, Westinghouse, 640/852 RPM, Type SK,

FR. 93. 120 VOLT D.C. MOTORS 1_304 HP, Westinghouse, 900 RPM, Shunt Wound,

Horizontal, Pedestal Bearing. 3—25 HP, G.E., Type CDM, 1200 RPM, Horizontal, 2 B.B., unused. Removed from M.G. Sets. 6—7% HP, Westinghouse Type SR, FR 43, Stab. •Sh. Wd., 1750 RPM.

STEERING GEAR MOTORS 2—General Electric, 30 HP, 230 V, DC, 600 RPM,

Stab. Sh. Wd., Type CDM, Fields Continuous Duty,

Armature 1 Hr. 1—Westinghouse, 35 HP, 230 V, DC, 850 RPM,

Stab. Sh. Wd., Type SK, Fr. 123, Fields Continuous

Duty, Armature 1 Hr.

SHIP'S LIGHTING M-E SETS 230 V, DC/115 V, DC. Ship's Lighting M.G. Sets for

C3-S1-A-3 150 K.W. and Moore built C2 100 K.W.

SPECIAL D.C. GENERATORS 3—Unused, G.E., 15 KW, 100 A, 15 V, Type CDM, 1200 RPM, 2 B.B., D.P. Generators.

MOTOR-GENERATOR SETS

Unused Surplus in Original Boxes

Janette M-G Sets. Input: 1.75 HP, 230 V, DC, 7.2

Amperes, 1800 RPM. Output: 1-KVA (.85 KW), 115/1/60, 4 ball bearing, with speed regulator, and with noise filters. Navy Type CJM-21151, con- tinuous duty. Net weight 435#, Dimensions 44"

L, 19%" W, 18%" H. Instruction book and parts list included.

D.C. MARINE CONTROLLERS 1—Cutler-Hammer, 250 HP, 230 V, DC,

No. 232 793A14. 2—General Electric, 225 HP, 230 V, DC,

CR 5430-B32D. 6—Westinghouse, 100 HP, 230 V, DC, Type 8585A S0-1B4636. 1—Cutler-Hammer, Unused, 50 HP, 230 V,

DC, No. C280981A290, Contactor Panel for

Stern Anchor Haulage Winch. Many others from y4 HP and up—115 and 230 V.

CIRCUIT BREAKERS 2 and 3 Pole Air Breakers, 2 and 3 Pole

Molded Case Navy Type Breakers, 2 and 3 Pole Trip Elements for Molded Case

Breakers.

Zidell's __

Generators . . . This is a partial list of

Westinghouse, General Electric,

Delco, Allis-Chalmers genera- tors ... for every purpose ... the right price! ••P 2—500 KW, 120/240 V, Westinghouse FR.

CB813.7, 750 RPM, 2 Pedestal Bearing, with Bal- ance Coils. Removed from GM 8-278 Engines. 2—250 KW, 120/240 V, Westinghouse, 1200 RPM,

Single Pedestal Bearings. Balance Coils not avail- able, Type 12S18P107PH, removed from Turbines. 2—150 KW, 120 V, G.E., Type CDM-1348-S, Form

HA, Model 25G 340,1800 RPM, Compound Wound,

Horizontal 2 B.B. 1—150, 120 V, G.E., Type CDM, Form AA, Model 24G, 1200 RPM, Compound Wound, Horizontal, 2

B.B. 6—100 KW, 120/240 V, Westinghouse, Type SK,

FR. 143.8, 1800 RPM, Single Ball Bearings. Bal- ance Coils available. 3—100 KW, 120/240 V, Delco, 1200 RPM, Single

Bushed Bearings, with Balance Coils. Removed from Superior GDB-8 Engines. 1—100 KW, 120/240 V, Allis-Chalmers, 1200

RPM, Single Sleeve Bearing, Shunt Wound, Type 4—14-45-13, removed from GM 3-268A Engine. 10—90/165 KW, Westinghouse, 125/400 Volt,

Type SK, FR. 185, Shunt Wound, separately ex- cited (120 V), 1200 RPM, Horizontal, 2 B.B. 4—75 KW, 120 V, G.E., Type CDM-1234, Mod. 24GA71,1200 RPM, 2 Ball Bearing, Tapered Shaft.

Removed from Motor-Generator Sets. 6-60 KW, 120 V, Westinghouse, Type SK, FR i43,

Style 3B2855-PH, 1800 RPM, 1 B.B. Removed from

Turbines. 6—60 KW, 120 V, Westinghouse, Type SK, FR. 153-L, Style 1B4632,1200 RPM, Compound Wound,

Horizontal, 2 B.B.

A.C. OR D.C. M-G SETS

From 250 Watts to 500 KW in 115 Volt, 230 Volt and 120/240 Volt, 3 Wire DC. Any drive including

Synchronous Motor. Let us have your inquiries. r 1

ZIDELL for Electrical Equipt, tremendous stock of electrical equipment at the right prices.

ZIDELL EXPLORATIONS, INC.

Contact

Hugh Sturdivant (503) 228-8691 3121 S.W. Moody

Portland, Ore. 97201

Telex: 36-701

RECONDITIONED

MOTOR GENERATOR SETS

Bogue. Input: 230 V, DC, 57A, 15 HP. Output: 10 KVA, PF .8,120 V, 60 cy., 10.

Fidelity. Input: 15 HP, 230 V, DC. Output: 12.5

KVA, 10 KW, 120/1/60.

Bogue Electric. Input: 15 HP, 230 V, DC. Out- put: 12.5 KVA, 10 KW, 120/1/60.

Burke Electric. Input: 20 HP, 230 V, DC. Out- put: 25 KVA, 12.5 KW, 120/1/60.

Star Kimble. Input: 30 HP, 230 V, DC. Output: 25 KVA, 20 KW, 120/1/60. ideal. Input: 40 HP, 230 V, DC. Output: 31.3

KVA, 25 KW, 450/3/60.

Star. Elec. Input: 40 HP, 230 V, DC. Output: 33.4 KVA, 25 KW, 450/3/60.

General Elec. Input: 230 V, DC, 40 HP. Output: 25 KW, 480 V, 60 cy., 30, 34A, 1800 RPM.

Star Elec. Input: 125 HP, 240 V, DC, Output: 93.75 KVA, 75 KW, 450/3/60.

MANY SMALLER UNITS IN STOCK

Marathon. Input: 1 HP, 115 V, DC, Output: .500

KVA, .425 KW, 115/1/60.

Bludworth. Input: .75 HP, 115 V, DC, Output-. .500 KVA, .450 KW, 115/1/60.

Century. Input: 1.5 HP, 115 V, DC. Output: .750

KVA, .600 KW, 125/1/60.

Elect. Prod. Input: 1.5 HP, 115 V, DC. Output: 1 KVA,115/1/60.

Allis-Chalmers. Input: 14 Amp, 115 V, DC. Out- put: 1.250 KVA, 1 KW, 115/1/60.

Cont. Elect. Input: 6 HP, 115 V, DC. Output: 2.9

KW, 440/3/60.

Louis AIMs. Input. 10 HP, 105/130 V, DC, Out- put: 7.5 KVA, 440/3/60.

Cont. Elect. Input: 12 HP, 120 V, DC. Output: 7.5 KVA, 440/3/60.

Continental. Input: 50 HP, 115 V, DC. Output: 50 KVA, 25 KW, 120/3/60.

Need 3 Wire 120/240 Volts DC for Shore Power? Motor-Generator Sets and Engine

Driven Units from IS KW to 500 KW ... Let us quote.

UIRIES Dry Transformers • AC & DC Gear Motors • Centrifugal Fans • Propeller

Fans • Port Hole Fans • Bracket Fans • Salinity Panels • Salinity Indicator

Cells • Electric Telegraphs • Rudder

Angle Indicators • Diesel Engine

Starting Contactors • AC & DC

Switchboards

ALSO RADIO, RADAR & ELECTRONIC EQUIPMENT

Maritime Reporter