Page 23: of Maritime Reporter Magazine (February 2, 2006)
Read this page in Pdf, Flash or Html5 edition of February 2, 2006 Maritime Reporter Magazine
February 2006 23
Bayonne Dry Dock
Reports Strong Year
Bayonne Dry Dock & Repair in Bayonne New Jersey recorded a busy 2005, with business prospects looking good for the coming year as well. According to a com- pany spokesman, the company noted an upswing in
Navy business in 2005, which included the drydocking of the USNS Shughart (T-AKR), a Large, Medium- speed, Roll-on/Roll-off Ships, or LMSR. The 900-ft. ship entered the shipyard in July and was out a month later in August 2005. The main focus of the work included ultra high pressure water blasting and paint- ing, and encompasses mechanical work as well. The company received a second contract for this type of ship, and was expecting the USNS Mendonca (T-AKR 303) to arrive on a 45-day stay on February 12. Work to this ship — which was christened in 1999 at
Avondale in New Orleans — includes modifications to its main engine propulsion exhaust system. In addition to the above work, the shipyard reports vibrant activity in repair and topside work on a variety of commercial ships, barges and tugs
Circle 40 on Reader Service Card
New Machinery Space Fire
Protection
Marioff's offers a new machinery space flooding total fire protection system dubbed HI-FOG MT4. With the system, the company claims there is no need to evacu- ate personnel, seal the space or shut off the ventilation.
By immediate activation, the fire is contained and extinguished in its infancy and the damage can be min- imized. HI-FOG MT4 is touted as an alternative to tra- ditional fire fighting systems and has passed the latest
IMO fire test requirements, as defined in MSC/Circ. 1165, adopted in May 2005.
The key feature of HI-FOG MT4 is that it can be acti- vated the second a fire is detected. The extinguishing media is plain, fresh water in the form of water mist, so an activation will not result in equipment corro- sion. No foam or chemicals are used, so the system does not present any harm to people in the space. The system can be full scale tested regu- larly to ensure that it is always in working condition and to demonstrate its operation to the crew. Finally, there is no need to divert to a port for recharging the system, as the system uses a pump unit rather than compressed gas. The system has been designed to pro- vide both total flooding and local application (IMO
MSC/Circ. 913), using the same pump unit, tubing and spray heads. Using one integrated system saves on component, installation, maintenance as well as train- ing costs. HI-FOG also is an efficient fire extinguish- ment system. It has proven itself in actual ship fires, which typically have been extinguished in about a minute from the moment the fire started.