Page 28: of Maritime Reporter Magazine (August 15, 1971)

Read this page in Pdf, Flash or Html5 edition of August 15, 1971 Maritime Reporter Magazine

BOSTOn MLS 313 E. BALTIMORE ST.* BALTIMORE 2, MD

Main Office: LExington 9-1900 • Marine Dept.: ELgin 5-5050

CO. 17 18 19 3500 H.P. G.E. — C-3 OR VICTORY

H.P.—8-stage—6159 RPM—serial 62043

L.P.—8-stage—3509 RPM—serial 62042

G.E.I. 16263 6000 H.P. G.E.— NORTH CAROLINA C-2

H.P.—8-stage—serial 78040

L.P.—7-stage—serial 78043

G.E.I. 16262

VICTORY SHIP AP2 H.P. & L.P. TURBINES

NEW — UNUSED — 6000 HP SETS

G.E.—H.P. & L.P.—with throttle valve

Westinghouse—L.P.—with throttle valve

Allis-Chalmers—H.P. & L.P.—with throtle valve

TURBO GENERATOR SETS

WESTINGHOUSE 440/3/60 200 KW UNIT

GENERATOR: Westinghouse 200 KW—250 KVA— 450/3/60—1200 RPM—80% PF—with 40 KW—120

VDC on same shaft. GEAR: 9989/1200 RPM—double helical. TURBINE: Westinghouse—540 PSI—super- heat 322°F. Test 930 PSI 800°TT. Also operates 615

PSI—850°TT.

WESTINGHOUSE 60 KW 120 VDC

M-20-EH 120 VDC—1800 RPM TURBINE: M-20-EH—20 lbs- dry & saturated—25" vacuum. 7283 RPM. GEAR: 7283/1800. GENERATOR: 60 KW—120 VDC—500 amps—SK—stab, shunt wound. 300 KW

WORTHINGTON-MOORE

CROCKER-WHEELER

UNITS

AP2 ExMedina Victory units. Worthington-Moore turbine—440 lbs—740°TT—28'/2" vac.—type S4— 5-stage—6097 RPM—serial 7547 & 7548. GEAR: 14x7—6097/1200. GENERATOR: Crocker-Wheeler 300

KW 120/240 DC—1250 amps—type 102-H—com- pound—973643—999759—armature flange 8%"— bolt circle 7"—12 holes. Also new armature in stock (weighs 1840 lbs). Also have 2 units—generator 102

HP—300—KW120/240—stab, shunt—1200 RPM.

VICTORY 300 KW

WESTINGHOUSE TURBO

GENERATOR SET 440# — 740°F — 5930 RPM — 2A-9794-15-16-17 — coupling non-recessed on steam end of pinion—53,4".

GENERATOR: Westinghouse 300 KW—120/240 DC— 1250 amps—1200 RPM—C.B. 208.4. 1000 KW G.E. TURBO

GENERATOR—READY

TO GO—WITH A.B.S.

TURBINE; Type FSN—eight stage—9268 RPM—525 lbs —825°TT or 590 PSI & 0° superheat. Turbine serial No. 53729. GEAR: Serial 54804 —9268/3600. GENERATOR: Serial 5596572—1000

KW—450 volt 3-phase 60 cycle—3600 RPM—0.8

PF—type ATB—2-pole—complete with air cooler. EX-

CITER: EDF—10.2 KW—120 volts—4-pole—3600

RPM—direct conected. UNIT JUST COMPLETELY

OVERHAULED & IN EXCELLENT CONDITION—READY

TO INSTALL. 13

UNUSED 500

KW 120/240 VDC

BALDWIN/ALLIS

CHALMERS DIESEL

GENERATOR SET

ENGINE: Baldwin-DeLaverne 725 HP— 12%"xl5JA" —8 cyl.—500 RPM—air starting. Dry weight 54050 lbs. GENERATOR: Allis-Chalmers 500 KW—120/240

VDC—500 RPM—550 RPM overspeed. 60°C rise- class B insulation—3-wire—25% unbalance—2083 amps—stab, shunt—open—drip-proof—self-ventilated —8-poles.

UNUSED 100KW

SUPERIOR DIESEL

GENERATOR SET

GENERATOR: 120/240 VDC —417 amps—stab, shunt— 1200 RPM. DIESEL: Superior

GBD-8—8 cyl.—5'/2x7.

UNUSED 10 KW SUPERIOR

DIESEL GENERATOR SET

GENERATOR: Delco 10 KW — 120 VDC —83.3 amps— 1200 RPM. ENGINE: Superi- or diesel—2 cyl.—41/2 x53/i -—-15 HP — heat exchanger cooled.

TURBINE ROTORS

MAIN PROPULSION 19 STAGE

WESTINGHOUSE

H.P. ROTOR FOR

AP2 VICTORY

Reconditioned — balanced— with ABS. Serial 4A-2079— type B—19 stage reaction blades. Excellent — just out of shop. 13" Flange diameter with 14 bolts.

SPECIAL!

COMPLETE TURBINE

OR ROTORS 8500 HP G.E. C-3 Victory—Sun C-4's

L.P.—Serial 77943 H.P. Serial 77942

G.E.I. 16263

AUX. GEN. ROTORS 14 NEW L.P. BLADE RINGS for large 8500 H.P. Victory

Joshua Hendy Westinghouse 15 16

NEW 8500 H.P.

G.E. TURBINES

Large Victory or C-3

H.P. #72271 L.P. 72272 1 0 BOXES SPARE PARTS, TOOLS &

FITTINGS. WITH MANEUVERING VALVES.

ALSO AVAILABLE

U.S.M.C.

RECONDITIONED SET

H.P. & LP.

With 13 boxes spare parts. H.P. 77994—L.P. 77987—with maneuvering valves. 20 250 KW & 300 KW

ALLIS-CHALMERS ROTORS

Typical serial No. 3067—will interchange with most 250 KW & 300 KW Allis-Chalmers as in- stalled on Victory's and Moore C2-C3 vessels. 21 22 300 KW 5965 RPM JOSHUA HENDY

Turbine—3H-69 Gear—-52269

Turbine—3H-52 Gear—52252

Turbine—3H-62 Gear—5226

T-2 ROTORS,STATORS

COOLERS, ETC.

ELLIOTT 10-STAGE MAIN PROPULSION

TURBINE ROTOR #28702—Ex-Texas Trader—will interchange with large

G.E. 1st Row—1 1/8" to shroud—13/16" O A H 2nd Row—1 7/16" to shroud—1 9/16" O A H. 23 24 25 26

G.E.

MAIN GENERATOR

STATOR

A.B.S,—ready to go—mfg. by Eniott for G.E.—over G.E design.

WESTINGHOUSE

MAIN GENERATOR

AIR COOLER

Reconditioned with A.B.S.

UNUSED G.E. MAIN GENERATOR

AIR COOLER

PUMPS

VICTORY AP2 MAIN

CIRCULATOR

Ingersoll-Rand — 1 8 VCM— 20" x 18"—10,500—10 lbs.

MOTOR: 75 HP—Allis Chal- mers—230 VDC—670 RPM.

Spare unused armature. Mo- tor frame F.B.V.—162.

DIESEL GENERATOR SETS

G.M. 6-71 DIESEL

GENERATOR SET 60 KW— 440/3/60 — 1200

RPM—with switchgear. 350 KW 120/240 VDC

DIESEL GENERATOR SET

Ingersoll-Rand heavy duty type S engine—8 cyl.— 505 HP—10'/2 x 12. GENERATOR: G.E. 350 K.W. 120/240—600 RPM—switchgear. Good condition— as removed from Grace Line ships. 250 KW DIESEL

GENERATOR SET

ENGINE: Enterprise 12x15

DSG-6—6 cyl.—450 RPM crank No. 50J. GENERATOR:

Westinghouse 250 KW—120 /240 DC—1040 amps—450

RPM. Typical serial No. 3S- 10P-913. Complete with switch gear. $12,500.

LARGE G.E.

MAIN PROPULSION

SCHENECTADY

TURBINE ROTOR

Turbine serial 77418—reconditioned with certificate.

Just out of Beth shop 1970.

AUXILIARY GENERATOR ROTORS

DORV—325M—T-2 Tanker Aux. Generator.

WESTINGHOUSE

MAIN PROPULSION

REVOLVING FIELD

Ex-Ohio Sun—A.B.S.—ready to go. Serial 25R10

WESTINGHOUSE

MAIN GENERATOR

STATOR

A.B.S.—ready to go—certifi- cate 70BA5297 —May 19, 1970—Rewound.

Maritime Reporter