Page 29: of Maritime Reporter Magazine (June 1974)
Read this page in Pdf, Flash or Html5 edition of June 1974 Maritime Reporter Magazine
DIESEL
GENERATOR SETS 350 KW DIESEL
GENERATOR SET
ELECTRIC
PROPULSION
MOTOR 1 Available. 515 HP—230 volts DC—shunt wound — 1040/1400 RPM—1660 amps—120 volts DC exciter. 8 10
ALSO SUITABLE FOR COMPANIES
OPERATING AN NET TENDERS
TURBO
GENERATOR SETS 400 KWWESTINGHOUSE
TURBO GEN SETS FOR
BETH. SPARROWS PT.
HULLS 400 TO 4500;
QUINCY HULLS 1600 400 KW (500 KVA)—80% PF—1200 RPM—450/3/ 60. TURBINE: 585 lbs—840°TT—28'/2" vacuum— 9018 RPM—serial 10A4462-3 & 10A4462-4. GEAR: 9018/1200 RPM. A.C. GENERATOR: 500 KVA—400
KW—450 volts—641 amps—80%PF—3 phase 60 cycle—1200 RPM—CR 40°—excitation amps 41 — excitation voltage 120. Instruction book 5442. Switch- gear available.
LOW-PRESSURE
UNUSED 300 KW G.E. 120/240 VOLT DC
TURBO-GENERATOR SET
GENERATOR: 300 KW—120/240 VDC—1250 amps— 1200 RPM. REDUCTION GEAR: 8.344:1— 10012/ 1200 RPM—type S-182. TURBINE: DOR418N—449
H.P.—10012 RPM—working pressure 180/220 PSIG
WESTINGHOUSE 440/3/60 200 KW UNIT
GENERATOR: Westinghouse 200 KW—250 KVA— 450/3/60—1200 RPM—80% PF—with 40 KW—120
VDC on same shaft. GEAR: 9989/1200 RPM—double helical. TURBINE: Westinghouse — 540 PSI—super- heat 322°F. Test 930 PSI 800°TT. Also operate 615
PSI—850°TT. 1250 KW G.E. 10-STAGE
TURBO GENERATOR
SET
TURBINE: 525—615 PSI—S50°TT—7938 RPM—10- stage—type FSN. GEAR: Single helix—7938/3600.
GENERATOR: 1250 KW—450/3/60/3600—.80 PF— type ATB with surface air cooler. Overload 25%— 2 hours—1563 KW. 11 6 EQUAL-TO-NEW
LATE TYPE 500 KW
SHIPS SERVICE TURBO
GENERATORS 1962—DeLaval. Very lit- tle use. Completely pre- served with rotors and di- aphragms crated sepa- rately. TURBINE: DeLaval —585 PSI — 840°TT—6- stage—6391 RPM—class
CD — Also suitable 440 lbs.—740°TT—25" vac. GEAR: 6391/1200 RPM.
GENERATOR: Allis-Chalmers — 450/3/60. Totally enclosed, with static exciter and voltage regulator system. Weight 17,665 lbs. Complete with latest dead front switch gear. Also available are the con- densers, circulating and condenser pumps. All very up-to-date, compact construction. Turbines will easily handle 600 KW if up-grading is desired. 12 AP2 VICTORY WORTHINGTON-MOORE
CROCKER-WHEELER 300 KW UNIT
TURBINE: 440 PSI—740°TT—28'/2" vacuum—type
S4 — 5-stage —6097 RPM — serial 7547 & 7548.
GEAR: 6097/1200. GENERATOR:- 300 KW—120/240 volts DC—1250 amps—compound wound—973643— 999759. Armature flange 8V2"; B.C. 7"—12 holes.
ALSO NEW ARMATURES IN' STOCK & 300 KW
SHUNT ARMATURES. 13
TWO 538 KW
WESTINGHOUSE
T-2 AUX. GENERATORS (COMPLETE)
TURBINE: 538 KW @ 5010 RPM—438 PSIG— 750°TT—28V2" vacuum. GEAR: 5010/1200 RPM.
A.C. GENERATOR: 400 KW 450/3/60/1200—0.8
PF. DC EXCITER: 32.5 KW—120 volts (variable voltage)—shunt—4-pole—DC excitation 5 KW.
ALWAYS WELL MAINTAINED BY MAJOR OIL CO.
TURBINES & ROTORS
MAIN PROPULSION 14 15 16
BETH. CLASS—13,600 H.P.
Sparrows Point & Quincy 1600 hulls. H.P. turbine cos- ing only. Excellent blading & labyrinth packing.
H.P. & L.P. COUPLINGS
I Set—for Beth Class 13,600 HP 4400 hulls and
Quincy 1600 hulls.
G.E. 6690 HP @ 7062 RPM
HIGH PRESSURE 8-STAGE
TURBINE 835 lbs—840°TT—#83341—originally built for Esso
Christobol—Newport News.
T-2
TURBINES & ROTORS 17 2 COMPLETE T-2
G.E. TURBINES #61818 and #61834—large Lynn—all stages magnafluxed.
ROTOR WILL INTERCHANGE WITH
ELLIOTT MAIN TURBINE
Will Sell Rotors Separately 18 19
T2-SE-A1
MAIN PROPULSION
ROTOR—G.E.
Large Schenectady — serial 77418-—reconditioned Beth- lehem Steel 1970—all stages magnafluxed.
T-2 TANKER
UNUSED—4 UNITS AVAILABLE
AUX. G.E. TURBO GEN. ROTORS ««SK®== DORV — 325M — 5645 RPM — for 525 KW G.E. 20 21 • ttOUNP THc . ^nunrrii,.
Main Office: (30
TURBO GElv — iP- !
TURBINE: 1 1 Stage type FN4— 8145 RPM—3V2" : absolute back pressure—complete steam with seal regu
GEAR: Type S-195A—reduction 8145 RPM to 1200
GENERATOR: 1500 KW —450 volts—2405 amps- enclosed. Insulation: Class B stator and rotor. Temper thermometer. Mfg type ATI—form HL. Oil lubricatec sump in turbo generator set base. Generator coolin —120 volts —1 10 amps—40°C rise—frame 654—
GENERAL INFORMATION: Overload rating 2 hours- weight 36,000 lbs. Guaranteed steam flows & condi flange. The set will carry 1500 KW with steam cond flange. The set will withstand 644 PSI and 850°F. at exhaust flange: 50% Load — 750 KW — 75% Load — 1125 KW — 100% Load — 1500 KW —
Exhaust flange size: 18" x 38" rectangular.
GENERATOR: 400 KW 450 volts 3-phase 1200 RPA sulation—natural self-ventilated cooling. Exciter: 5C
GEAR: Single helix—single reduction—10059/12001
TURBINE: Six stage—10059 RPM—525 PSI—825°| tors. OVERLOAD CONDITIONS AT NORMAL STEAA overload for 2 hours at normal conditions; overload | turbine generator will deliver full load output 400 capable of withstanding 634 lbs PSIG 850°TT.
STEAM FLOWS 100% Load — 400 KW AC 75% Load — 300 KW AC 50% Load — 200 KW AC
When operating at 575 PSIG & 0° Superheat and l| 125% Load — 500 KW AC 100% Load — 400 KW AC 75% Load — 300 KW AC
UNIT DESIGNED FOR NAVY FOR DD692 CLASS
HOUSE 8316.
Since Westinghouse and G.E. built them for the san able.
DIMENSIONS: OAL 10' lOKs"—OAW 4'WV2"—0/
TOTAL WEIGHT: 14,855 lbs. 2" steam inlet—17" Round exhaust—2OV2" bolt
UNIT DIMENSIONS OAL 16' 33/a"—OAW 6'6' 350 KW—120/240 volts DC—600 RPM—compound wound G.E. generator with switchgear. ENGINE: Inger- soll-Rand—heavy-duty type S—505 HP—101/2x12— reconditioned to ABS. 250 KW DIESEL
GENERATOR SET v u-A ENGINE: Enterprise 12 x 15 (({lUil DSG-6 — 6 cyl. — 450 RPM
WtrMawP crank No. 50J. GENERATOR: .. QE^raaSOl Westinghouse 250 KW—120 - >'mi: V> ' t S&; /240 DC—1040 amps—450 •BSHaFTSVPP* RPM- Typical serial No. 3S- «"'«*' V*"fV-«J[ 10P-913. Complete with • * * - switch gear.
EMERGENCY GENERATOR
SUPERIOR 75KW 120/240 VOLT D.C.
DIESEL GENERATOR SET
With switchgear. ENGINE:
Radiator cooled Superior GBD -8 — 6-cylinder—1200 RPM.
GENERATOR: Electric Ma- chinery Co.—120/240 volts
DC—316 amps—1200 RPM _ —stab, shunt. 415 KW 250 VOLT DC
GM 6-278 DIESEL GENERATOR
SETS
ENGINE: GM Model 6-278— 6-cylinder—8V2 x 10'/2 — 2- cycle — 800 RPM — complete with heat exchanger. GENE-
RATOR: Allis-Chalmers—415
KW—250 volts DC—800 RPM —1660 amps—shunt wound.
Top mounted exciter—800/ 1600 RPM—208 amps—type
EB5-123. Pilot exciter 21/2KW —120 volts DC—shunt wound—20.8 amps. Both exciters belt-driven from main generator shaft.