Page 32: of Maritime Reporter Magazine (November 1971)

Read this page in Pdf, Flash or Html5 edition of November 1971 Maritime Reporter Magazine

BOSTOn METALS * 313 E. BALTIMORE ST. . BALTIMORE, MD. 21202

Main Office: (301) 539-1900 Marine Dept.: (301) 355-5050 15 1000 KW G.E. TURBO

GENERATOR—READY

TO GO—WITH A.B.S.

TURBINE; Type FSN—eight stage—9268 RPM—525 lbs —825»TT or 590 PSI & 0" superheat. Turbine serial No. 53729. GEAR: Serial 54804 —9268/3600. GENERATOR: Serial 5596572—1000

KW—450 volt 3-phase 60 cycle—3600 RPM—0.8

PF—type ATB—2-pole—complete with air cooler. EX-

CITER: EDF—10.2 KW—120 volts—4-pole—3600

RPM—direct conected. UNIT JUST COMPLETELY

OVERHAULED & IN EXCELLENT CONDITION—READY

TO INSTALL.

DIESEL

GENERATOR SETS

G.M. 6-71 DIESEL

GENERATOR SET 60 KW— 440/3/60 — 1200

RPM—with switchgear. 250 KW DIESEL

GENERATOR SET

ENGINE: Enterprise 12x15

DSG-6—6 cyl.—450 RPM crank No. 50J. GENERATOR:

Westinghouse 250 KW—120 /240 DC—1040 amps—450

RPM. Typical serial No. 3S- 10P-913. Complete with switch gear. $12,500.

UNUSED 500

KW 120/240 VDC

BALDWIN/ALLIS

CHALMERS DIESEL

GENERATOR SET

ENGINE: Baldwin-DeLaverne 725 HP—12%"x15VV' —8 cyl.—500 RPM—air starting. Dry weight 54050 lbs. GENERATOR: Allis-Chalmers 500 KW—120/240

VDC—500 RPM—550 RPM overspeed. 60°C rise- class B insulation—3-wire—25% unbalance—2083 amps—stab, shunt—open—drip-proof—self-ventilated —8-poles.

UNUSED 100KW

SUPERIOR DIESEL

GENERATOR SET

GENERATOR: 120/240 VDC —-4^7 amps—stab, shunt— 1200 RPM. DIESEL: Superior

GBD-8—8 cyl.—5Vix7.

UNUSED 10 KW SUPERIOR

DIESEL GENERATOR SET

GENERATOR: Delco 10 KW — 120 VDC —83.3 amps— 1200 RPM. ENGINE: Superi- or diesel—2 cyl.—4Vix5% — 15 HP — heat exchanger cooled. 37 250 KW

COOPER

BESSEMER

DIESEL

GENERATOR SET 250 KW Cooper Bessemer constant duty diesel gener- ator set. ENGINE: Cooper Bessemer FS-6—6 cylinder —83\/A" x 11" bore and stroke—900 RPM—3968 cubic inches. GENERATOR: General Electric 250 KW—312

K.V.A.—type ATI—frame 975Y—450 volts—3 phase —60 cycle—80% P.F. continuous. EXCITER: 4.5 KW —120 volts. With switch gear.

TURBO

GENERATOR SETS

WESTINGHOUSE 440/3/60 200 KW UNIT

GENERATOR: Westinghouse 200 KW—250 KVA— 450/3/60—1200 RPM—80% PF—with 40 KW—120

VDC on same shaft. GEAR: 9989/1200 RPM—double heliaal. TURBINE: Westinghouse—540 PSI—super- heat 322° F. Test 930 PSI 800°TT. Also operates 615

PSI—850°TT.

TURBINE ROTORS 10 WESTINGHOUSE 60 KW 120 VDC

M-20-EH 120 VDC—1800 RPM TURBINE: M-20-EH—20 lbs- dry & saturated—25" vacuum. 7283 RPM. GEAR- 7283/1800. GENERATOR: 60 KW—120 VDC—500 amps—SK—stab, shunt wound. 11 300 KW

WORTHINGTON-MOORE

CROCKER-WHEELER

UNITS

AP2 ExMedina Victory units. Worthington-Moore turbine—440 lbs—740°TT—28'A" vac.—type S4— 5-stage—6097 RPM—serial 7547 & 7548. GEAR: 14x7—6097/1200. GENERATOR: Crocker-Wheeler 300

KW 120/240 DC—1250 amps—type 102-H—com- pound—973643—999759—armature flange 8Vi"— bolt circle 7"—12 holes. Also new armature in stock (weighs 1840 lbs). Also have 2 units—generator 102

HP—300—KW120/240—stab, shunt—1200 RPM.

VICTORY 300 KW

WESTINGHOUSE TURBO

GENERATOR SET 440# — 740°F — 5930 RPM — 2A-9794-15-16-17 — coupling non-recessed on steam end of pinion—53/i".

GENERATOR: Westinghouse 300 KW—120/240 DC— 1250 amps—1200 RPM—C.B. 208.4. 13

G.E. 600 KW

GEARED

TURBO GENERATOR

SETS

G.E. 600 KW geared turbo generator sets—52b lbs—825«>F. TURBINE: Type FN3-FN-20—6-stage —882 HP—600 KW—525/565 lbs. G—superheat 355/371 °F—exhaust pressure 1" abs. Test steam chest 850# G. 10033 RPM—6390 lbs steam flow per hour. REDUCTION GEAR: Single helix—single reduction—10033/1200. GENERATOR: G.E.—600

KW—450/3/60—1200 RPM—type ATI—0.8 PF— 961 amps continuous—2 hours 25% overload— (750 KW) 1200 amps—5 minutes (900 KW) 1400 amps. Totally enclosed—water cooled—amb. temp, reg. 50°C. EXCITER: 7.5 KW—120 VDC—direct connected. Complete with rheostat type voltage regulator & motor operated generator field rheo- stat.

FURNISHED WITH ABS

OR LLOYD'S CERTIFICATE 14

WESTINGHOUSE

MAIN GENERATOR

LEVER OPERATED

CONTROL CUBICLES — COMPLETE —

MAIN PROPULSION 19 STAGE

WESTINGHOUSE

H.P. ROTOR FOR

AP2 VICTORY

Reconditioned — balanced— with ABS. Serial 4A-2079— type B—19 stage reaction blades. Excellent—just out of shop. 13" Flange diameter with 14 bolts. 17

SPECIAL!

COMPLETE TURBINE

OR ROTORS 8500 HP G.E. C-3 Victory—Sun C-4's

L P.—Serial 77943 H.P. Serial 77942

G.E.I. 16263 18

NEW L.P. BLADE RINGS for large 8500 H.P. Victory

Joshua Hendy Westinghouse 19 20

NEW 8500 H.P.

G.E. TURBINES

Large Victory or C-3

H.P. #72271 L.P. 72272 10 BOXES SPARE PARTS, TOOLS &

FITTINGS. WITH MANEUVERING VALVES.

ALSO AVAILABLE

U.S.M.C.

RECONDITIONED SET

H.P. & L.P.

With 13 boxes spare parts. H.P. 77994—L.P. 77987—with maneuvering valves. 21 22 23 3500 H.P. G.E. — C-3 OR VICTORY

H.P.—8-stage—6159 RPM—serial 62043

L.P.—8-stage •3509 RPM-

G.E.I. 16263 •serial 62042 6000 H.P. G.E. — NORTH CAROLINA C-2

H.P.—8-stage—serial 78040

L.P.—7-stage—serial 78043

G.E.I. 16262

VICTORY SHIP AP2 H.P. & L.P. TURBINES

NEW — UNUSED — 6000 HP SETS

G.E.—H.P. & L.P.—with throttle valve

Westinghouse—L.P.—with throttle valve

Allis-Chalmers—H.P. & L.P.—with thr®tle valve

AUX. GEN. ROTORS 24 250 KW 8> 300 KW

ALLIS-CHALMERS ROTORS

Typical serial No. 3067—will interchange with most 250 KW & 300 KW Allis-Chalmers as in- stalled on Victory's and Moore C2-C3 vessels. 300 KW 5965 RPM JOSHUA HENDY 25 Turbine—3H-69 Turbine—3H-52 Turbine—3H-62 Gear—52269 Gear—52252 Gear—52262 350 KW 120/240 VDC

DIESEL GENERATOR SET

Ingersoll-Rand heavy duty type S engine—8 cyl.— 505 HP—10'/2 x 12. GENERATOR: G.E. 350 K.W. 120/240—600 RPM—switchgear. Good condition— as removed from Grace Line ships. 100 KW

G.M. 3-268A

DIESEL

GENERATOR SET new. ENGINE: G.M. 3-268A—3 cylinder—6y2" x 7" bore and stroke. GENERATOR: General Electric— 100 KW—440 volts—3 phase—60 cycle.

Maritime Reporter

First published in 1881 Maritime Reporter is the world's largest audited circulation publication serving the global maritime industry.